Won-Door Fireguard Fire Rated Assembly
View the link above for the following information regarding Fire Rated Assembly:
FIREGUARD 20, 60, 90, 180
FIREGUARD COLOR CHART
FIRE DOOR SELECTION GUIDE
SPECIFICATIONS: PART 1 – GENERAL
1.01 SUMMARY OF WORK
1.02 RELATED SECTIONS
1.03 QUALITY ASSURANCE
1.04 SUBMITTALS
1.05 DELIVERY, STORAGE, AND HANDLING
1.06 COORDINATION BY GENERAL CONTRACTOR
1.07 WARRANTY
SPECIFICATIONS: PART 2 – PRODUCTS
2.01 MANUFACTURER AND MODEL
2.02 FIRE RATING
2.03 REMOTE MONITORING AND CONTROL
2.04 MATERIALS
2.05 COLOR
SPECIFICATIONS: PART 3 – EXECUTION
3.01 PREPARATION BY GENERAL CONTRACTOR
3.02 INSPECTION
3.03 INSTALLATION
3.04 DEMONSTRATION
STRAIGHT DOOR – HEAD DETAIL
STRAIGHT DOOR – PLAN VIEW SINGLE PARTING
STRAIGHT DOOR – PLAN VIEW BI-PARTING
STRAIGHT DOOR – ELEVATION SIDE VIEW
STRAIGHT DOOR – ELEVATION FRONT VIEW
STRAIGHT DOOR – HEAD DETAIL STEEL PAN HEADER
POCKET DEPTH CHART INSTRUCTIONS
STRAIGHT DOOR – POCKET DEPTH CALCULATION CHART
CURVED DOOR – HEAD DETAIL
CURVED DOOR – PLAN VIEW SINGLE PARTING
CURVED DOOR – PLAN VIEW BI-PARTING
CURVED DOOR GUIDELINES
CURVED DOOR – ELEVATION FRONT VIEW
POCKET DEPTH CHART INSTRUCTIONS
CURVED DOOR – POCKET DEPTH CALCULATION CHART
POCKET COVER DOOR GUIDELINES
POCKET COVER DOOR DETAIL
POCKET MOUNTED MOTOR OPERATOR ELECTRICAL DIAGRAM
LARGE DOOR MOTOR OPERATOR ASSEMBLY WIRING DIAGRAM
ASL – ADVANCED SYNCHRONIZED LOGISTICS
OPTIONAL KEY SWITCH
CCOM ROCKER SWITCH
OPTIONAL VISION PANEL
OPTIONAL SINGLE DOOR DISPLAY
OPTIONAL MULTIPLE EXIT HARDWARE DETAIL
Won-Door Fireguard Temperature Rise
View the link above for the following information regarding Fireguard Temperature Rise:
FIREGUARD TEMPERATURE RISE
GUIDELINES FOR TEMPERATURE RISE DOORS
SPECIFICATIONS: PART 1 – GENERAL
1.01 SUMMARY OF WORK
1.02 RELATED SECTIONS
1.03 QUALITY ASSURANCE
1.04 SUBMITTALS
1.05 DELIVERY, STORAGE, AND HANDLING
1.06 COORDINATION BY GENERAL CONTRACTOR
1.07 WARRANTY
SPECIFICATIONS: PART 2 – PRODUCTS
2.01 MANUFACTURER AND MODEL
2.02 FIRE RATING
2.03 REMOTE MONITORING AND CONTROL
2.04 MATERIALS
2.05 COLOR
SPECIFICATIONS: PART 3 – EXECUTION
3.01 PREPARATION BY GENERAL CONTRACTOR
3.02 INSPECTION
3.03 INSTALLATION
3.04 DEMONSTRATION
POCKET DEPTH CHART INSTRUCTIONS
POCKET DEPTH CALCULATION CHART
Won-Door Fireguard Moveable Fire Wall
View the link above for the following information regarding Fireguard Moveable Fire Wall:
GUIDELINES FOR FIREGUARD MOVEABLE FIRE WALL
SPECIFICATIONS: PART 1 – GENERAL
1.01 SUMMARY OF WORK
1.02 RELATED SECTIONS
1.03 QUALITY ASSURANCE
1.04 SUBMITTALS
1.05 DELIVERY, STORAGE, AND HANDLING
1.06 COORDINATION BY GENERAL CONTRACTOR
1.07 WARRANTY
SPECIFICATIONS: PART 2 – PRODUCTS
2.01 MANUFACTURER AND MODEL
2.02 FIRE RATING
2.03 MATERIALS
2.05 COLOR
SPECIFICATIONS: PART 3 – EXECUTION
3.01 PREPARATION BY GENERAL CONTRACTOR
3.02 INSPECTION
3.03 INSTALLATION
3.04 DEMONSTRATION
MFW – HEAD DETAIL
MFW – PLAN VIEW
MFW – ELEVATION SIDE VIEW
MFW – ELEVATION FRONT VIEW
POCKET DEPTH CHART INSTRUCTIONS
POCKET DEPTH CALCULATION CHART
POCKET COVER DOOR GUIDELINES
POCKET COVER DOOR DETAILS
POCKET MOUNTED MOTOR OPERATOR ELECTRICAL DIAGRAM
OPTIONAL KEY SWITCH